# Kymoscope sample files

**Every file here is synthetic.** The signals are generated by Kymoscope from physical models (no
customer, partner or measured data), so they can be shared freely and used in demos. They are written
in the formats the instruments and software of each industry export, with their usual channel names,
units and rates. Each sample hides a known finding; its story (`docs/<id>.md`, and
https://kymoscope.com/samples) says what was planted, when it starts and which alerts find it.

In Kymoscope, **Sample data** (the flask in the left rail) opens a sample with its worksheets, charts and
alerts: see https://kymoscope.com/docs/sample-data. Any file can also be dropped onto the app; the files of
one sample are opened together (the CAN log with its `.dbc`). Files are read in the browser and never uploaded.

Generators: `tests/fixtures/samples/gen_*.py` (deterministic; rerun one to rebuild its files, then
`gen_thumbs.py` for the sizes and thumbnails of the site).

## Motorsport & sim racing

| Sample | Files | Format | Size | What it shows |
| --- | --- | --- | --- | --- |
| [`gt3-stint`](docs/gt3-stint.md) | `gt3-race-stint-barcelona.mf4` | ASAM MDF 4 | 12.4 MB | 30 laps of a GT3 race stint at Barcelona, 55 channels at 100, 20, 5 and 1 Hz. Rubber on the radiator intake lifts the engine temperature 0.7 °C a lap, a full-course yellow hides it for two laps, and the rear left tyre starts a slow puncture seven laps before the stop. |

## Test & validation

| Sample | Files | Format | Size | What it shows |
| --- | --- | --- | --- | --- |
| [`emotor`](docs/emotor.md) | `emotor-dyno-sweep.mf4` | ASAM MDF 4.10 | 7.3 MB | A 600 s test of a 180 kW PMSM e-drive: full-load sweep 500 to 12,000 rpm, peak hold, coolant flow sag, regen. Phase currents and DC link at 20 kHz, 27 bench channels at 100 Hz. One end-winding sensor runs 14 K ahead, passes 155 °C and the inverter cuts the torque; a 0.3 s PT100 open circuit is not a temperature. |
| [`ev-can`](docs/ev-can.md) | `ev-can-log.mf4` (275 kB)<br>`ev-can-log.dbc` (2 kB) | MDF 4 bus logging + DBC | 277 kB | Five minutes of vehicle CAN, 78,000 frames: VCU, inverter, BMS and a multiplexed cell-voltage message. Cell 07 has 1.7 times the resistance of its neighbours. Open both files together; the DBC decodes the log in the browser. |
| [`modal`](docs/modal.md) | `modal-hammer-plate.mat` | MATLAB v5 MAT | 3.0 MB | Impact-hammer modal test at 25 kHz: five hits, three accelerometers, modes at 182, 547, 1310 and 2730 Hz; the fourth hit is a double hit. |

## Batteries & energy

| Sample | Files | Format | Size | What it shows |
| --- | --- | --- | --- | --- |
| [`cell-aging`](docs/cell-aging.md) | `cell06-aging-arbin.csv` (6.3 MB)<br>`cell02-aging-arbin.csv` (6.3 MB)<br>`cell-aging-statistics.csv` (45 kB) | Arbin CSV | 12.6 MB | 165 cycles of 21700 NCA cells over four weeks. Cell 06 plates lithium from cycle 60 (capacity 4.82 to 4.14 Ah, DCIR 29 to 37 mOhm); cell 02 is a healthy cell of the batch; the statistics table has eight cells, one row a cycle. |
| [`fuelcell`](docs/fuelcell.md) | `fuelcell-stack-60c.tdms` | NI TDMS | 8.8 MB | 60-cell PEM stack, 30 minutes: polarization staircase to 1.6 A/cm² and a dynamic load. Cell 37 floods at high load and recovers at every anode purge; the two end cells run low at full load. |
|  | `fuelcell-polarization-10c.csv` | CSV (preamble + units row) | 1.5 MB | Not in the app library: a 10-cell short stack polarization curve at 10 Hz, as a test station exports it. |

## Energy & process

| Sample | Files | Format | Size | What it shows |
| --- | --- | --- | --- | --- |
| [`process-unit`](docs/process-unit.md) | `unit12-e201-28d.csv` (9.9 MB)<br>`unit12-fic204-2h.csv` (2.2 MB) | Historian CSV (wide + long) | 12.1 MB | Feed cooler E-201 on cooling water: one row a minute for 39 tags over 28 days, plus a 1 s long-form export of a flow loop. The cooler fouls while its temperature loop hides it, a flow valve sticks, a strainer plugs until the pump cavitates, a tower fan trips. |
| [`grid-fault`](docs/grid-fault.md) | `grid-fault-ag-132kv.cff` | COMTRADE 2013 (CFF) | 308 kB | 132 kV feeder relay record at 12.8 kHz: phase-A-to-ground fault (8 kA with DC offset), single-pole trip, open-pole period, auto-reclose at 700 ms, with pickup, trip and breaker status. |

## Manufacturing & quality

| Sample | Files | Format | Size | What it shows |
| --- | --- | --- | --- | --- |
| [`imm-check-ring`](docs/imm-check-ring.md) | `imm2-shots-20d.csv` (5.2 MB)<br>`imm2-curves-healthy.tdms` (4.2 MB)<br>`imm2-curves-worn.tdms` (4.2 MB) | Euromap 63 CSV + NI TDMS | 13.6 MB | 36,261 shots of an injection moulding machine over 20 working days, one row a shot. The check ring wears: the cushion sinks from 5.9 to 2.3 mm and short parts rise from 0.4 % to 11 % while every setting stays put. Two 500 Hz curve files, healthy against worn. |
| [`press-die-wear`](docs/press-die-wear.md) | `press2-strokes-22d.csv` | CSV, one row a stroke | 2.1 MB | 19,231 strokes of a stamping press over 22 working days. The die wears: peak tonnage 2,364 to 2,563 kN, burr 0.03 to 0.105 mm, scrap 1.2 to 7.6 %. A hard coil, a slug and a frozen die thermocouple tell themselves apart. |

## Vibration & condition monitoring

| Sample | Files | Format | Size | What it shows |
| --- | --- | --- | --- | --- |
| [`fan-bearing`](docs/fan-bearing.md) | `fan-bearing-trend-35d.csv` (714 kB)<br>`fan-bearing-snapshots-25k6.h5` (3.2 MB) | CSV trend + HDF5 waveforms | 3.9 MB | An 18.5 kW process fan, one row every 10 minutes for 35 days, and three 25.6 kHz waveform captures. An outer-race defect shows in the envelope on day 18, in kurtosis on day 20 and in ISO 20816-3 velocity only on day 31. |
| [`gearbox`](docs/gearbox.md) | `gearbox-runup-25khz.h5` | HDF5 | 4.9 MB | Gearbox run-up 600 to 4200 rpm at 25 kHz: the gear-mesh order crosses a 1.6 kHz housing resonance, a bearing accelerometer carries an outer-race defect, plus a tacho and a 100 Hz group. Made for a spectrogram. |

## Pharma & food

| Sample | Files | Format | Size | What it shows |
| --- | --- | --- | --- | --- |
| [`batch-reactor`](docs/batch-reactor.md) | `r101-batches-28d.csv` | Historian CSV | 8.5 MB | Jacketed reactor R-101, 149 batches in 28 days at 30 s, 15 tags. The jacket fouls from day 14 (heat-up 40 to 57 minutes); three overshoots in the hold put three batches under the purity specification. |
| [`retort`](docs/retort.md) | `retort3-day-1s.csv` (8.9 MB)<br>`retort-batches-4w.csv` (55 kB) | Controller log CSV | 9.0 MB | Steam retort 3, one production day at 1 s and four weeks of batch records of three retorts. The control RTD reads 1 °C high, so every batch gets less F0 than it should; a short vent and a boiler trip give two lots under 3. |

## Research & education

| Sample | Files | Format | Size | What it shows |
| --- | --- | --- | --- | --- |
| [`eeg`](docs/eeg.md) | `eeg-oddball-32ch.edf` | EDF+ | 7.7 MB | 32-channel EEG at 500 Hz, four minutes: eyes open, eyes closed (10.2 Hz alpha), an auditory oddball with a P300 at Pz; blinks and a jaw clench. 121 annotations. |
| [`hdemg`](docs/hdemg.md) | `hdemg-biceps-8x8.bdf` | BDF+ (24-bit) | 12.0 MB | HD-EMG 8 × 8 grid on biceps at 2048 Hz plus force, holds at 30 % and 60 % MVC. Motor unit potentials travel along the rows at 4.2 m/s; R5C3 is a poor contact. |
| [`motor-imagery`](docs/motor-imagery.md) | `eeg-motor-imagery.xdf` | XDF (LabRecorder) | 6.6 MB | A 16-channel EEG stream at 500 Hz and a marker stream on its own clock. 19 cues: the mu rhythm fades over the motor cortex opposite the imagined hand. |
| [`teaching-lab`](docs/teaching-lab.md) | `teaching-lab-usb6001.tdms` | NI TDMS | 502 kB | A pendulum, an RLC step response, a DC motor and a cooling block on an NI USB-6001, every parameter stated so a student’s fit can be checked; one RLC step clips at the 10 V rail. |